Automatic equipment troubleshooting

2023-06-15


Check all power, air and hydraulic sources

Power supply, including the power supply for each piece of equipment and the power electricity for the workshop, i.e. all the power sources that can be involved in the equipment.

Air sources, including the air pressure sources required for the pneumatic units.

Hydraulic sources, including the operation of the hydraulic pumps needed for the hydraulic units.

In 50% of the troubleshooting problems, errors basically occur with the power supply, the air source and the hydraulic source. Problems with the power supply, for example, include faults with the entire workshop power supply, such as low power supply, burnt out fuses, poor contact with the power plug, etc.; problems caused by an air or hydraulic pump not being turned on, a pneumatic triplex or duplex not being turned on, a relief valve or some pressure valve in the hydraulic system not being opened, etc. These are the most basic problems and are usually the most common ones.

 

Checking sensor positions for offsets

Due to negligence on the part of the equipment maintenance staff, there may be errors in the position of certain sensors, such as not being in place, faulty sensors, faulty sensitivity, etc. Always check the sensing position and sensitivity of the sensors, adjust them promptly in case of deviation and replace them immediately if they are broken. Very often, if the supply of power, air and hydraulic sources is guaranteed to be correct, more often the problem is the failure of the sensor. Especially with magnetic induction sensors, due to long-term use, it is likely that the internal overlays stick to each other and cannot be separated, resulting in a normally closed signal, which is a common problem with this type of sensor and can only be replaced. In addition, due to the vibration of the equipment, most of the sensors will become loose in position after long-term use, so it is important to check frequently whether the sensors are correctly positioned and firmly fixed during daily maintenance.

 

Checking relays, flow control valves, pressure control valves

Relays, like magnetic induction sensors, can develop a sticking overlap over a long period of time, which prevents the electrical circuit from working properly and needs to be replaced. In pneumatic or hydraulic systems, throttle valve openings and pressure regulating springs in pressure valves, can also become loose or slip with the vibration of the equipment. These devices, like the sensors, are components in the equipment that require routine maintenance. Therefore, it is important that these devices are carefully checked during daily work.

 

Checking electrical, pneumatic and hydraulic circuit connections

If none of the above three steps reveal any problems, then check all circuits. Look for disconnections in the circuit, especially in the wire channels which have not been cut by the wire channels due to pulling. Check the air hoses for damaging creases. Check for blockages in the hydraulic fluid lines.
To check the circuit in this step, use the necessary multimeter, set to buzzer and check the circuit access. If the air hose is badly creased, replace it immediately. The hydraulic oil hose should be replaced as well.

After ensuring that the above steps are correct, the fault may only appear in the controller, but it can never be a programming problem! First of all, do not be sure that the controller is ruined, as long as there has not been a serious short circuit, the controller has internal short circuit protection and a general short circuit will not burn up the controller.
First, check if there are any devices with high frequency interference near the controller. If so, move it away immediately. If outdoors, heavy lightning may also cause the controller to not work properly for a moment. In this case, remove all possible interfering devices and then reboot the controller.

Next, if the restart does not work, check the controller wiring for loose, poor contact.
Finally, if the wiring is correct. Determine if there is a problem with the memory card of the PLC. Replace the card with a new one, download the program and check if the previous memory card is faulty.